- Temperature Instruments[10]
- Instrument Parts & Accessories[5]
- Other Wires[4]
- Electrical Wires[10]
- Instrumentation Cables[10]
- Other Home Appliance Parts[1]
- Resistors[1]
- Sensors[1]
- Industrial Heater[10]
- Refrigeration & Heat Exchange Parts[3]
- Other Electrical Equipment[1]
- Electric Heater Parts[3]
- Wiring Harness[1]
- Aluminum Wire[2]
- Other Electronic Measuring Instruments[2]
- Flanges[1]
- Terminal Blocks[1]
- Steel Pipes[3]
- Other Graphite Products[1]
- Pressure Gauges[10]
- Stainless Steel Bars[3]
- Stainless Steel Strips[1]
- Stainless Steel Pipes[2]
- Metal Building Materials[4]
- Flow Meters[1]
- Other Measuring & Analysing Instruments[5]
- Contact Person : Ms. Yuan April
- Company Name : Jiangsu Plaza Premium Electric Instrument Co., Ltd.
- Tel : 086-0523-86155311
- Fax : 086-0523-83767111
- Address : Jiangsu,taizhou,Zhangguo Town Industrial Zone
- Country/Region : China
- Zip : 225722
thermocouple,RTD,sensor
Application It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from 0°C to 1300°C during various production process.Features1.With quick response, reducing dynamic error;
2.Optional installation methods;
3.Wide measuring range ;4.High mechanical strength, good pressure-resistant performanceOperation theoryThe electrodes of armored thermocouple are made of two different materials. the temperature difference between measuring end and reference end results in pyroelectric potential ,then the meter indicates the corresponding temperature to the pyroelectic potential.Mail technical parametersExecutive standard:IEC584IEC1515GB/T16839-1997JB/T5582-91
RTD Measuring range & Tolerance
Type | Graduation | Tolerance class | |||||
I | II | ||||||
Tolerance value | Measuring range°C | Tolerance value | Measuring range°C | ||||
WRNK | K | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 | ||
±0.004|t| | 375~1000 | ±0.0075|t| | 333~1200 | ||||
WRMK | N | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 | ||
±0.004|t| | 375~1000 | ±0.0075|t| | 333~1200 | ||||
WREK | E | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 | ||
±0.004|t| | 375~800 | ±0.004|t| | 333~900 | ||||
WRFK | J | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 | ||
±0.004|t| | 375~750 | ±0.004|t| | 333~750 | ||||
WRCK | T | ±1.5°C | -40~+125 | ±1°C | -40~+133 | ||
±0.004|t| | 125~350 | ±0.0075|t| | 133~1000 | ||||
WRPK | S | ±1°C | 0~+1100 | ±2.5°C | 0~600 | ||
±[0.003(t-1100)] | 1100~1600 | ±0.0025|t| | 600~1600 |